| Variants | - ITC-3 RACK 24/40: 19” rack model, max 24 signal groups and 40 loop detector inputs
- ITC-3 RACK 6/16: 11” rack model, max 6 signal groups and 16 loop detector input
- ITC-3 RACK 12/0: 11” rack model, max 12 signal groups and loop detector input from external modules
|
| System Voltage | 80-260 VAC |
| Colors | Light grey; RAL colour must be specified |
| Weight of the housing | 80 Kg |
| System voltage | 80–260 VAC |
| Supply voltage for signal heads | 40 VAC, 42 VAC, 48 VAC, 110 VAC, 220 VAC, 230 VAC, +/-15% |
| Max. Load | 3.7 kVA (24-phase) |
| Fuse protection for signal | - 35 A Typ C, 10 kA für das gesamte Gerät
- 2,1 A pro Ausgangsklemme
|
| Max. switching capacity | Max. 500 VA bei 230 VAC |
| Lamp switch types | Triac 24–230 VAC |
| Types of lamps/signal head | - 230 V lamps (40 – 150 W)
- 230 V LEDs (4 – 50 W)—Approval required
- 10.5 V overpressure lamps (20, 30 W)
- 10-/12 V halogen lamps (20, 30, 50 W)
- 110 V lamps (max. 150 W)
- 40 V standardized LED signal heads (1 – 9 W)
|
| Dimming | |
| Display elements | LCD touch panel 480 x 80 |
| Signal head cabling | Generally 1,5 mm² |
| Acknowledgement devices of signal | Known range of diverse suppliers |
| Pedestrian signal request devices | Known range of diverse suppliers |
| I/o interfaces | 5–48 V DC |
| Cabinet | 3 Standard sizes: - 600 mm x 420 x 1300
- 900 mm x 420 x 1300
- 1200 mm x 420 x 1300
|
| Communications | RS232, RS485, RS 422, CAN, Ethernet, USB |
| Certifications | - CE marking (includes EMC and low-voltage directive)
- EN 12675: 2000 Traffic signal controller, functional safety requirements
- EN 50293: 2012 Road traffic signal systems, electromagnetic compatibility
- EN 50556: 2011 Road traffic signal systems
- EN 60950-1:2006 Information technology systems, safety
- TR2500A Topas
|
Ambient temperature limits | -40C to +70C |
| Power consumption of control unit | Typical < 15W |
| Technical features (lamp load) | - Fully electronic design, central unit with 32-bit ARM processor
- 512 MB Flash, 256 MB RAM, can be expanded with SD cards
- Linux O/S
|
| Control centers | - SWARCO MyCity
- Omnia/Spot
- Arctic
- Optimus
- SCATS
- SCOOT
- NTCIP
- SWARCO Cloud
|
| Signal monitoring per lamp-switch output | - Two-channel setup based on fail-safe components
- Monitoring of unsafe signaling states
- Alarm message in case of contradictory signaling states and defective light sources
- Selective disabling of the partial node in which the unsafe signaling state has occurred
- All colors monitoring
|
| Operator control / data supply | - LCD display for fast access to operating states, alarms and system events
- Full range of diagnostic capabilities available via the web interface or central control mode
|
| Timer | |
| Flashing pulse | Freely programable duty cycle |
| Signal patterns for vehicles/pedestrians | Any signal pattern possible |
| Types of control | - Central control mode for road traffic
- Local mode, fixed time
- Local control, traffic actuated
- Manual mode
- Vehicle actuated
- Group control
- Phase/stage coordination
- Master/slave
- Adaptive local green wave/corridor
- Automatic annual switching routine
|
| Data logging | Polling of detector inputs at intervals of 10 ms, with configurable plausibility check. |
| Software | - LINUX operating system with RTAI real-time expansion
- ITC Firmware (real-time process, system process, traffic actuation, control center process)
|
| PC tools | ITC-PC, NGEN(Scats), CCOL, Teddy, Linsig(Scoot), LISA+ |